<aside> <img src="https://s3-us-west-2.amazonaws.com/secure.notion-static.com/f93f414d-943f-43e7-b870-18e474b3ef0b/blank.png" alt="https://s3-us-west-2.amazonaws.com/secure.notion-static.com/f93f414d-943f-43e7-b870-18e474b3ef0b/blank.png" width="40px" /> During and after the calibration process you should not adjust camera lenses.
</aside>
<aside> <img src="https://s3-us-west-2.amazonaws.com/secure.notion-static.com/f93f414d-943f-43e7-b870-18e474b3ef0b/blank.png" alt="https://s3-us-west-2.amazonaws.com/secure.notion-static.com/f93f414d-943f-43e7-b870-18e474b3ef0b/blank.png" width="40px" /> Calibration should be performed in the same light, in which an object will be scanned. If there is too much change of level in lighting conditions it is necessary to recalibrate the system. It is not allowed to carry the calibration procedure on direct sunlight.
</aside>
Full calibration dialog box opens automatically after the Configuration wizard or manually from the menu Configuration → Full calibration.
Calibration procedure:
<aside> <img src="https://s3-us-west-2.amazonaws.com/secure.notion-static.com/f93f414d-943f-43e7-b870-18e474b3ef0b/blank.png" alt="https://s3-us-west-2.amazonaws.com/secure.notion-static.com/f93f414d-943f-43e7-b870-18e474b3ef0b/blank.png" width="40px" /> Make sure that the plate size specified in the software matches the actual plate size written on its back side. Incorrect size may cause errors and geometric distortions on meshes.
</aside>
Small vertical discrepancies between the blue lines and field marks are acceptable and do not affect the quality of the setting. For large mismatches, it is recommended to adjust the vertical tilt angle of the scanning module relative to the calibration field.
The new detection algorithm allows calibration in the absence of several calibration field markers.
The absence of six large markers and three central ones is not allowed, because the orientation of the calibration field is detected and determined by them. It is not allowed to have two control corner markers, the center-to-center distance between which is nominal when measuring the deviations of each calibration step.
The absence of no more than 40% of markers is allowed, subject to the presence of those noted above.
In case if not all required marks are found on the image, you will also see an error message. It may mean the following: