For the work of the scanner it is necessary to point both cameras to the same position on the specified working distance. Install the calibration plate in front of the scanner on the found working distance (if you changed its position after the projector focusing procedure.

Turn on the Cross light mode and aim the scanner to the calibration plate. It is not necessary to combine cross with marks on the plate at this stage, the focused projector should be projecting a cross on any surface, located at the working distance from the scanner.

Install the cameras in position, corresponding to selected scan area. To do this, unscrew the mounting screws, move the camera to the desired position, and then put the screws back.

To set the maximum scanning area, the cameras are located at the greatest distance from each other. To set the minimum scanning area, the cameras are placed at a minimum distance from each other.

Next, rotate the cameras so that the vertical line of the light cross lies approximately on the central vertical blue line in the both camera views as shown below. After that, securely tighten the screws.

https://s3-us-west-2.amazonaws.com/secure.notion-static.com/1d9007ea-9008-4f38-a8ea-f6db3ca920f6/__-_1.png

Сведение камер - 1.png

https://s3-us-west-2.amazonaws.com/secure.notion-static.com/6753f034-8877-4df6-82cf-9cf94b066438/Question-mark---cropped.png

<aside> <img src="https://s3-us-west-2.amazonaws.com/secure.notion-static.com/0bb0b1c3-6c39-4545-95b7-88ec9a3a45b1/Blank_-_Spacer.png" alt="https://s3-us-west-2.amazonaws.com/secure.notion-static.com/0bb0b1c3-6c39-4545-95b7-88ec9a3a45b1/Blank_-_Spacer.png" width="40px" /> A small deviation between the right-hand and left-hand cameras in height does not affect the scan quality.

</aside>

<aside> ◀️ Previous

</aside>

<aside> ▶️ Next

</aside>